Part Number Hot Search : 
L02TB 1N5996B TTINY2 ATS04 89CIN 16NBS AS5DC6 820ALG
Product Description
Full Text Search
 

To Download TFS125C Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  TFS125C.doc version 1.2 12.07.00 vi telefilter filter specification tfs 125c 1/5 vi telefilter vectron international, inc. potsdamer stra?e 18 267 lowell road d 14 513 teltow / germany hudson, nh 03051 / usa tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 tel: (603) 598-0070 fax: (603) 598-0075 e-mail: tft@telefilter.com e-mail: vti@vtinh.com vi telefilter reserves the right to make changes to the product(s) and/or information contained herein without notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation measurement condition ambient temperature t a : 23 c input power level: 0 dbm terminating impedances at f c : input: 605 ? ?? -11 pf output: 620 ? ?? -11 pf characteristics remark: reference level for the relative attenuation a rel of the tfs 125c is the maximum of the pass band attenuation a max . the maximum of the pass band attenuation a max is defined as the insertion loss a e . the centre frequence f c is the arithmetic mean value of the upper and lower frequencies at the 1 db filter attenuation level relative to the insertion loss a e . the nominal frequency f n is fixed on 125 mhz without tolerance. the given values for the relative attenuation a rel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency f c is shifted due to the temperature coefficient of frequency tc f in the operating temperature range and due to a production tolerance for the centre frequency f c . data typ. value tolerance / limit insertion loss (reference level) a e max. 8,0 db min. 5,0 db nominal frequency f n - 125,0 mhz centre frequency f c 125,0 mhz db passband ripple within 150 khz min. 1,25 db relative attenuation a rel f n ..... f n 150 khz - max. 1,25 db f n 0,4 mhz...f n 0,6 mhz - min. 2,0 db *) f n 0,6 mhz...f n 1,2 mhz - min. .8,0 db f n 1,2 mhz...f n 1,8 mhz - min. 20,0 db f n 1,8 mhz...f n 3,4 mhz - min. 25,0 db f n 3,4 mhz...f n 9,5 mhz - min. 30,0 db f n 9,5 mhz.. f n 13 mhz - min. 43,0 db f n 13 mhz...f n +450 mhz - min. 55,0 db group delay **) max. 1,7 s group delay rippel **) within 150 khz max. 150,0 ns vswr: max. 2,3: 1 ip3 ***) min. 60,0 db operating temperature range - 10 c ... + 85 c temperature coefficient of frequency ( tc f ) ****) t.b.d frequency inversion temperature t o t.b.d input power level: max. 10,0 dbm *) the rejection is relative to the point of maximum insertion at centre frequency **) measured with smoothing; smoothing aperture 30 khz ***) modulation signals: f n and f n -28 mhz each of 10 dbm ****) ? f c (hz) = tc f (ppm/k2) x (to - t a ) 2 x f cat (mhz) generated: sabah checked/approved: www..net
TFS125C.doc version 1.2 12.07.00 vi telefilter filter specification tfs 125c 2/5 vi telefilter vectron international, inc. potsdamer stra?e 18 267 lowell road d 14 513 teltow / germany hudson, nh 03051 / usa tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 tel: (603) 598-0070 fax: (603) 598-0075 e-mail: tft@telefilter.com e-mail: vti@vtinh.com vi telefilter reserves the right to make changes to the product(s) and/or information contained herein without notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation construction and pin connection (all dimensions in mm) tfs 125c m46 13.3 6.5 max. datecode 2 1 10 8 4 9 12 11 10 5 3 7 6 50 ? ? ? ? matching network: l2 output 50 ohm c2 input 50 ohm c1 l1 saw 1,2,3,4,7,8,9,10 5 12 11 6 1 ground 2 ground 3 ground 4 ground 5 output rf return 6 output 7 ground 8 ground 9 ground 10 ground 11 input 12 input rf return date code: year+week k 1998 l 1999 m 2000 n 2001 ......
TFS125C.doc version 1.2 12.07.00 vi telefilter filter specification tfs 125c 3/5 vi telefilter vectron international, inc. potsdamer stra?e 18 267 lowell road d 14 513 teltow / germany hudson, nh 03051 / usa tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 tel: (603) 598-0070 fax: (603) 598-0075 e-mail: tft@telefilter.com e-mail: vti@vtinh.com vi telefilter reserves the right to make changes to the product(s) and/or information contained herein without notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation stability characteristics after the following tests the filter shall meet the whole specification: 1. shock: 500g, 18 ms, half sine wave, 3 sho cks each pl ane; din iec 68 t2 - 27 2. vibration: 10 hz to 500 hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; din iec 68 t2 - 6 3. damp heat: 25 c to 55c / 95% r.h. / 10 cycles (cycle) din iec 68 - 2 ? 30 db 4. resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "air reflow temperature conditions" on page 4; packing tape & reel: iec 286 - 3, with exception of value for n and minimum bending radius; tape type ii , embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: 1700 real of empty components at start: min 300 mm real of empty components at start including leader: min 500 mm trailer min 300 mm d o p o e f w p 1 embossed carrier tape cover tape g p 2 b o a o d 1 tape (all dimensions in mm) w : 24 0,3 po : 4 0,1 do : 1,5 + 0,1 e : 1,75 0,1 f : 11,5 0,1 g (min) : 0,60 p2 : 2 0,1 p1 : 12 0,1 d1(min) : 1,5 ao : 7,1 0,2 bo : 13,9 0,2 ct ct : 21,5 0,1 a c n w 1 w 2 reel (all dimensions in mm): a : 330 w1 : 24,40 +2,0 w2 (max) : 30,4 n (min) : 60 c : 13 0,5/-0.2 the minimum bending radius is 45 mm. the mounting surface of the filters faces the bottom side of the embossed carrier tape. the marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket hole s on the left side of the tape.
TFS125C.doc version 1.2 12.07.00 vi telefilter filter specification tfs 125c 4/5 vi telefilter vectron international, inc. potsdamer stra?e 18 267 lowell road d 14 513 teltow / germany hudson, nh 03051 / usa tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 tel: (603) 598-0070 fax: (603) 598-0075 e-mail: tft@telefilter.com e-mail: vti@vtinh.com vi telefilter reserves the right to make changes to the product(s) and/or information contained herein without notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation air reflow temperature conditions 1st and 2nd air reflow profile name: pre-heating periods main-heating periods peak temperature temperature: 150 c - 170 c over 200 c 255 c 5 c time: 60 sec. - 90 sec. 20 sec. - 25 sec. chip-mount air reflow profile time / sec. temperature / c 0 20 40 60 80 100 120 140 160 180 200 220 240 260 0 20 40 60 80 100 120 140 160 180 200 220 240 table for temperature vs. time during the air reflow process tolerance of temperatures: 5 c time / sec. temperature / c time / sec. temperature / c 0 23 140 160 10 34 150 161 20 46 160 164 30 60 170 170 40 80 180 180 50 103 190 205 60 121 195 230 70 134 200 255 80 143 205 230 90 150 210 205 100 154 215 180 110 156 220 165 120 158 230 140 130 159 240 120
TFS125C.doc version 1.2 12.07.00 vi telefilter filter specification tfs 125c 5/5 vi telefilter vectron international, inc. potsdamer stra?e 18 267 lowell road d 14 513 teltow / germany hudson, nh 03051 / usa tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 tel: (603) 598-0070 fax: (603) 598-0075 e-mail: tft@telefilter.com e-mail: vti@vtinh.com vi telefilter reserves the right to make changes to the product(s) and/or information contained herein without notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation history version reason of changes name date 1.0 - generation of specification according to hudson specification sabah 07.10.1999 1.1 - correction according to customer specification (nokia) sabah 27.03.2000 - ip3: instead of ?no statement? is 60 dbm - vswr (max): instead of 2.0:1 is 2.3:1 - rejection (f f n 13000 khz): instead of min. 60 db is min. 55 db - operational temperature range changed from -10 .... 80 c to -10 ..... 85 c 1.2 - the sprocket holes: instead of the right side of the tape is on the left side of the tape (according to customer requirement, e mail from: 7. juli.00) sabah 12.07.2000


▲Up To Search▲   

 
Price & Availability of TFS125C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X